The PetrolPlaza audio version is presented to you by UNITI expo, the leading retail petroleum and car wash trade fair in Europe.

OPW discussed new EPA regulations at 2018 PEI-NACS

Last week marked a pivotal moment for the retail fueling industry with the new EPA regulations coming into effect.



Last update:

Global fluid-handling solutions provider OPW fielded many questions from retailers around the pending U.S. Environmental Protection Agency’s (EPA) Underground Storage Tank (UST) Regulations at last week’s PEI Convention at the NACS Show in Las Vegas, Nevada. The new UST regulations went into full effect on October 13.

On July 15, 2015, the EPA published an update to the UST regulation and the state program approval regulation in the Federal Register. The revisions strengthened the 1988 federal UST regulations by increasing the emphasis on properly operating and maintaining UST equipment.

“The moment we’ve been helping distributors and site owners prepare for since 2015 has arrived, but the process is far from over for many fueling sites across the United States,” said Ed Kammerer, Director of Marketing and Global Product Strategy. “We received a lot of interesting feedback about the struggle to find contractors to get sites up to code. It’s now officially crunch time.”

There are four major regulatory requirements that all U.S. stations must be prepared for pertaining to new and existing UST systems.

  1. Testing of sumps and under-dispenser containment systems must be performed every three years if the system uses interstitial monitoring of the piping as its primary form of leak deterrence.
  2. Spill-bucket testing will be required every three years, unless the UST system is outfitted with double-wall spill buckets where the interstitial space is tested regularly. Some states already require spill-bucket testing every year.
  3. Compliance testing of repaired components: Whenever any component in the spill-protection, overfill-containment and secondary-containment areas of the UST system needs to be repaired, compliance testing of the repaired system must be completed within 30 days, regardless of whether or not an actual product release occurred.
  4. Overfill-prevention equipment inspections will be required every three years, except in states where they are already required annually.

“It’s important for each site owner to get their site compliant as soon as possible,” added Kammerer. “Not just for the safety of their customers and our environment, but for their business as non-compliance penalties are fierce.”